Digital Multi-Meter - DISCONTINUED

  • Digital Multi-Meter - DISCONTINUED
  • Tests: DC Voltage/ DC Current/AC Voltage/Diode & Continuity (audible)/Resistance & Transistor hFE
  • Display: 3.5 digits, 7 segment, 15mm high LCD
  • Data Hold: Freezes the last reading if this button is pushed. Pushing the button again will release data hold
  • "10A" Jack for Red test lead.
  • "COM" Jack for black test lead
  • "V, ohms, mA" for red test lead when testing voltage, resistance & current (except 10A) measurements
  • Maximum Voltage Between Terminals & earth ground: CAT II, 600V
  • Fuse Protection:200mA/250V
  • Power: 9V battery (NEDA 1604 or 6F22)
  • Display: LCD, 1999 counts, updates 2-3/sec.
  • Measuring Method: Dual-slope integration A/D converter
  • Over range Indication: Only figure "1" will appear on the display
  • Polarity Indication:"-" displayed for negative polarity
  • Operating Environment: 0 to 40 deg C (storage, 10-50 deg C)
  • Dimensions: 138mm tall, 69 mm wide, 31mm deep (5.5" x 2.5" x 1.25")
  • Weight: Approx 170g
  • Ships with test leads & Rubber Protective Holster
DC VOLTAGE

Range

Resolution

Accuracy

200mV

100µV

±0.5% of rdg ± 2 digits

2V

1mV

±0.5% of rdg ± 2 digits

20V

10mV

±0.5% of rdg ± 2 digits

200V

100mV

±0.5% of rdg ± 2 digits

600V

1V

±0.8% of rdg ± 2 digits

Overload Protection: 250V rms. For 200mV range and 600V dc or rms. Ac for other ranges

DC Current

Range

Resolution

Accuracy

200µA

0.1µA

±1% of rdg ± 2 digits

2mA

1µA

±0.5% of rdg ± 2 digits

20mA

10µA

±0.5% of rdg ± 2 digits

200mA

100µA

±1.5% of rdg ± 2 digits

10A

10mA

±3% of rdg ± 2 digits

Overload Protection: F 200mA/250V fuse (10A range unfused)

AC Voltage

Range

Resolution

Accuracy

200V

100mV

±1.2% of rdg ± 10 digits

600V

1V

±1.2% of rdg ± 2 digits

Overload Protection: 600V dc or rms. As for all ranges. Frequency range: 40Hz to 400Hz. Response: average responding, calibrated in rms. Of a sine wave.

Diode & Continuity

Range

Description

speaker pic

If continuity exists (about less than 1.5kO), built in buzzer will sound.

pic here

Show the approx forward voltage drop of the diode

Overload Protection 250Vdc or rms. Ac.

Resistance

Range

Resolution

Accuracy

200O

.01O

±0.8% of rdg ± 3 digits

2kO

1O

±0.8% of rdg ± 2 digits

20kO

10O

±0.8% of rdg ± 2 digits

200kO

100O

±0.8% of rdg ± 2 digits

20MO

1kO

±1.0% of rdg ± 2 digits

Maximum Open Circuit Voltage: 3.2V Overload Protection:250V dc or rms. As for all changes.

Transistor hFE Test

Range

Test Range

Test Current

Test Voltage

NPN & PNP

0-1000

Ib=10µA

Vce=3V


Digital Multi-Meter - DISCONTINUED

  • Product Code: T-003-000
  • Availability: Discontinued

This product is unavailable.

Contact us if you have any questions.